Mma-303 direct/indirect charge - maintenance – Ransburg MMA-303 Direct_Ind Charge Atomizer A12870 User Manual

Page 84

Advertising
background image

MMA-303 Direct/Indirect Charge - Maintenance

81

LN-9269-11.3

DISASSEMBLY PROCEDURES
(Cont.)

At the front of the atomizer, examine where the
tube is in relationship to the fitting hole location
of the shaping air manifold. If it is 90° or less
than where the tube exits the atomizer body,
you must install a loop in the tubing as shown in
“Installing Loop In Tubing” figure. Do not kink
tubing. Slide nut (A11276-00) and ferrule
(A11305-00) over the end of the tube as shown.

Installing Loop In Tubing

Insert end of tube into hole of shaping air mani-
fold. Slide ferrule and fitting forward and en-
gage threads by hand until thread stops. Tight-
en fitting using a 3/8-inch end wrench. Tighten
approximately 1/2 turn more (see “Inserting
Tube” figures). Make sure tubing will not be
pinched or kinked when outer shroud ins in-
stalled (see “Inserting Tube” figures).

Inserting Tube

Inserting Tube

Inserting Tube

Advertising