Mma-303 direct/indirect charge - maintenance, Disassembly procedures (cont.) – Ransburg MMA-303 Direct_Ind Charge Atomizer A12870 User Manual

Page 78

Advertising
background image

MMA-303 Direct/Indirect Charge - Maintenance

75

LN-9269-11.3

then tighten 1/2 turn more with a wrench. DO
NOT

over-tighten as this may damage cable.

Secure green wire with yellow stripe (attached
to high voltage cable) to any known good
earth ground, such as a water pipe, etc., using
the attached ring terminal.

DISASSEMBLY PROCEDURES
(Cont.)

Bell Cup Removal / Replacement

The bell cup should always be the first compo-
nent removed if any maintenance is per-
formed. Following the procedure will minimize
the risk of damage to the cup itself.

Lay the applicator on its side of a clean and
secure area, preferably an area where regular
maintenance is performed. Using the large
open end of the ball cup/combo wrench
(A12601-00) on the flats of the turbine shaft,
carefully hold the outside of the bell cup with
one hand while applying a clockwise force to
the wrench. The bell cup is a right hand thread
and must be turned counter-clockwise to re-
move.

Atomizer Removal

N O T E

Bell Cup Removal

Place the bell cup in a safe, secure place.
Carefully inspect the cup for any damage. If
there is any damage to the cup, it must be re-
placed.

!

C A U T I O N

Failure to replace a damaged bell cup will

cause premature turbine failure. Warranty
will not be honored if the bell cup is dam-
aged.

N O T E

For removal of the 30mm or 55mm bell cups,
you must use bell cup wrench A11284-00.
For the 65mm bell cups you must use
AA12061-00 bell cup wrench.

A11284-00 BELL CUP WRENCH

A12061-00 BELL CUP WRENCH

USE ON 30M AND 55MM BELL CUPS ONLY

USE ON 65MM BELL CUPS ONLY

Bell Cup Wrenches