Set-up instructions, Important – Robinair 178012K Recovery, Recycling, Recharging Unit User Manual

Page 11

Advertising
background image

Model 178002K/178012K Recovery/Recycling/Recharging Unit

9

Important!

For an R-134a
tank, connect the
36" yellow hose
to the RED High
Side Service
Hose Port.
Connect the
other end to the
air purge valve
on the tank.

The vacuum pump is shipped without oil in the reservoir. Before starting the unit, you
must fill the pump with oil. Two 16-ounce (472 milliliters) bottles of oil are included with
your unit.

11. Remove the black plastic plug from the pump’s oil fill port. Attach the flexible spout

and cap to the bottle of oil included with your unit. This makes it easier to fill the
pump.

12. Add one-half of a bottle of vacuum pump oil to the vacuum pump.

13. Press SHIFT/RESET and ENTER at the same time, then press “VACUUM.”

The vacuum pump will start and run continuously. While the pump is running, pour
oil into the pump’s oil fill port until the level of oil is even with the line of the pump
reservoir sight glass. Replace the black plug on the oil fill port.

14. Let the pump run for about five (5) minutes to remove any air from the unit.

15. To turn off the pump, press HOLD/CONT. Then press SHIFT/RESET to exit

the diagnostics mode.

16. Disconnect the blue 96” hose from the filter housing fitting on the unit. Disconnect

the red 96” hose from the air purge fitting on the tank.

17. Connect the 36” yellow hose to the air purge fitting on the tank.

18. Replace the black cap on the filter housing fitting.

Before using a new tank, you must purge its nitrogen charge and pull it into a vacuum.

Diagram of Vacuum Pump Components

Oil Filler Tube

Inlet

Pump Exhaust

Oil Fill Port

Sight Glass

Oil Drain
Fitting

Important!

Be sure the
pump is running
when adding oil.
Do not overfill
the pump. The
approximate oil
charge is 13 oz.
(384 milliliters).

Set-Up Instructions

Advertising
This manual is related to the following products: