Model 178002K/178012K Recovery/Recycling/Recharging Unit

3

GENERAL OPERATING GUIDELINES

• The voltage at the unit must be ±10% of the unit’s rated voltage. Extension cords must

be a minimum of 14 AWG and kept as short as possible.

• To interrupt any procedure (other than clearing), press HOLD/CONT. Press

HOLD/CONT again to resume operation.

• The system oil should be drained at the end of every recovery or recycling procedure,

during the clearing process, or whenever oil is visible in the sight glass.

• The indicator light will tell you the state of the refrigerant coming into the unit during

recovery. ON is liquid, OFF is vapor. The light is not used for recycling since the
refrigerant coming from the tank will always be a liquid.

• Some tanks have slightly different valve configurations. Be sure to connect the red

hose to the GAS (vapor) valve and connect the blue hose to the LIQUID valve.

• To ensure that the scale readings are as accurate as possible, be sure the tank is not

touching the sides of the cart before each procedure.

• To minimize mixing of refrigerants, follow the steps in Changing Refrigerant Types

when switching between refrigerant types.

• When the unit is first turned on, the display shows either:

“134a” — Indicates R-134a automotive refrigerant using

1

/

2

” Acme fittings.

“R12” — Indicates all other refrigerant types using

1

/

4

” flare fittings.

“door” — Indicates the unit has been cleared; select R-12 or R-134a.
Be sure you have selected the correct refrigerant type.

• Be sure to use the correct hose set for the refrigerant type selected:

Hose Set

Tank Hoses (3)

System Hoses (2)

R-134a automotive

36”,

1

/

2

” Acme with

96”, one Quick Seal

double Quick Seal

with one quick coupler

R-12 automotive

36”,

1

/

4

” flare with

96”,

1

/

4

” flare with

double Quick Seal

double Quick Seal

All other refrigerant types

36”,

1

/

4

” flare with

96”,

1

/

4

” flare with

single Quick Seal

ball valve

Introduction

• Present UL approval addresses refrigerants R-12 and R-134a. UL approval is

pending for all other refrigerants including new substitutes and blends.