Operating guidelines – Robinair 178012K Recovery, Recycling, Recharging Unit User Manual

Page 32

Advertising
background image

© 2000 Robinair, SPX Corporation

30

Segment A — Indicates in which mode the unit is operating:

PROGRAM — The unit is in the programming mode, which allows you to pro-
gram vacuum time and refrigerant weight or to review the existing program.

HOLD — This mode is used to change a refrigerant tank or to interrupt the
vacuum/charging/recovery cycles.

AUTOMATIC — Indicates that the unit is running in a given cycle and will auto-
matically stop when the cycle is complete. One exception: the recycling process
must be stopped by pressing HOLD/CONT.

Segment B — Indicates that the unit is either evacuating the A/C-R system or recover-
ing, recycling, or recharging refrigerant or that the unit is ready to be programmed for
one of the following functions (Use the chart on the next page as a quick reference for
interpreting Segment B messages).

VACUUM

With PROGRAM, indicates that the unit is ready to be programmed for vacuum.

With AUTOMATIC, indicates that the vacuum pump is running; the number
displayed counts down in minutes and seconds, showing the amount of time remain-
ing.

With HOLD, indicates that HOLD/CONT was pressed to interrupt the vacuum
cycle.

RECYCLE

With AUTOMATIC, indicates the unit is recycling refrigerant from the tank.

CHARGE

With PROGRAM, indicates that the unit is ready to be programmed for the amount
of refrigerant to be charged into the A/C-R system; on the keypad enter the charge
in pounds and hundredths of a pound or kilograms, depending on the measurement
mode selected.

With AUTOMATIC, indicates the unit is charging refrigerant into the A/C-R
system; the number shown on the digital display counts down, showing the remain-
ing amount of refrigerant to be dispensed.

Operating Guidelines

Advertising
This manual is related to the following products: