Model 178002K/178012K Recovery/Recycling/Recharging Unit

19

Weight Example *

* The display shows the weight of
refrigerant added to the tank.

This process takes about 45 minutes. You can interrupt it at any time by pressing

HOLD/CONT once. Press HOLD/CONT again to resume operation, or press

SHIFT/

RESET

to end the process. The transfer of new refrigerant is limited by weight to leave

space (about 6 pounds of refrigerant) in the unit tank for recovery purposes.

6.

When using R-12, close the supply valve on the source tank (when using a
disposable tank, turn it right side up first). Carefully disconnect the 96 inch
(244-cm) blue low-side hose from the 6-inch (15.2-cm) yellow adapter, and
then remove the yellow adapter from the source tank.

When using R-134a,

,

,

,

, close the supply valve on the source tank, (when using

a disposable tank, turn it right side up first). Carefully disconnect the 96 inch
(244-cm) blue low-side hose from the low-side connector port adapter and
then remove the adapter from the source tank.

7. Press

RECOVER

. The hose will be pulled into a partial vacuum and the unit will

turn off automatically. If the hose is partially clear, the unit will display "CH-P".
Press

HOLD/CONT

to finish clearing the hose. Close the low-side manifold

valve.

Any non-condensable gases in the tank can be removed during the

recycling sequence. Your unit is now ready for use.

Operating Instructions

IMPORTANT!

Be sure to close
both tank valves
when the unit is
not in use.
Inspect the unit
periodically for
leaks. The
manufacturer of
the recovery/
recycling unit
does not reim-
burse for lost
refrigerant.