Model 178002K/178012K Recovery/Recycling/Recharging Unit

13

message changes to "CONT". Close the oil drain valve. Press any key to complete
the system oil separator clearing process. When this stage is complete, the message
changes to "CL-c."

5. If you need to change hoses for the next refrigerant type, go to Step 6. If you do

not need to change hoses, press SHIFT/RESET and go to Step 7.

6. To start the self-clearing process, press VACUUM while the “CL-c” message is

displayed. The “Clr” message then displays and the vacuum pump runs for 5
minutes before shutting off automatically. The “door” message will then display.

7. Close the tank valves and disconnect the red, blue and yellow hoses from the tank.

Then remove the tank from the unit.

8. If you are using the same hoses for the next refrigerant type, go to Step 12. If you

need to change the hoses, go to Step 9.

9. Disconnect all five (5) hoses from the lockout box fittings. If you need to change the

door position on the lockout box, go to Step 10. If you do not need to change the
door position, go to Step 11.

10. Slide the door on the lockout box to expose the fittings needed for the next refriger-

ant type. Press SHIFT/RESET to lock in that position.

11. Connect the correct hoses for the next refrigerant to the fittings in the lockout box.

Be sure to use the correct hose set for the refrigerant type selected:

Hose Set

Tank Hoses (3)

System Hoses (2)

R-134a automotive

36”,

1

/

2

” Acme with

96”, one Quick Seal

double Quick Seal

with one quick coupler

R-12 automotive

36”,

1

/

4

” flare with

96”,

1

/

4

” flare with

double Quick Seal

double Quick Seal

All other refrigerant types

36”,

1

/

4

” flare with

96”,

1

/

4

” flare with

single Quick Seal

ball valve

12. Place a tank (already set up for the next refrigerant) on the unit. Connect the red,

blue and yellow hoses to the appropriate tank fittings.

The unit is now ready to process the next refrigerant type.