Maintenance procedures, Changing the vacuum pump oil – Robinair 178012K Recovery, Recycling, Recharging Unit User Manual

Page 25

Advertising
background image

Model 178002K/178012K Recovery/Recycling/Recharging Unit

23

CHANGING THE VACUUM PUMP OIL

When the vacuum pump has run for a total of 10 hours, the “OIL” message will flash on
the display to signal that an oil change is needed. To change the vacuum pump oil, follow
these steps:

1. Turn on the MAIN POWER switch. The display shows the selected refrigerant

type.

2. Press SHIFT/RESET and the messages “PROGRAM VACUUM MINUTES

15:00” display.

3. Press VACUUM. The display shows the “OIL” message.

4. Remove the black plastic plug on the oil fill port.

5. Remove the oil drain cap from the vacuum pump, then drain the contaminated oil

into a suitable container (be sure to dispose of it properly). Replace the oil drain
cap.

6. Attach the flexible spout and cap to the oil bottle and pour approximately six (6)

ounces of vacuum pump oil into the oil fill port.

7. Be sure the manifold valves are closed, then press SHIFT/RESET and ENTER

at the same time to reset the ten-hour timer.

8. Press VACUUM. While the pump is running, slowly add new vacuum pump oil

until the oil level is even with the line on the reservoir’s sight glass.

9. Replace the black plastic plug on the oil fill port.

10. Turn off the MAIN POWER switch if you are finished.

Diagram of Vacuum Pump Components

Oil Filler Tube

Inlet

Sight Glass

Oil Fill Port

Pump Exhaust

Oil Drain
Fitting

Maintenance Procedures