Troubleshooting – Robinair 178012K Recovery, Recycling, Recharging Unit User Manual

Page 41

Advertising
background image

Model 178002K/178012K Recovery/Recycling/Recharging Unit

39

Troubleshooting

RECOVERY OPERATION

Compressor does not start

Problem:

Main power switch is off

Solution:

Turn on switch

Problem:

Power cord is not plugged in or there is no power at plug

Solution:

Check circuit for power

Problem:

“FULL” message shows on digital display

Solution:

Change tanks (see Installing a Tank and Pulling A Vacuum)

Problem:

“HI-P” message shows on digital display

Solution:

Be sure tanks valves are open and hoses are properly connected to the
tank, or
Check for air in the tank (recycle tank to purge any air), or
Check the scale calibration (see Checking the Scale Accuracy)

Problem:

“CH-F” message on digital display

Solution:

Remove and replace the filter-drier (see Replacing the Filter-
Drier
), and be sure to pull a vacuum before continuing

Runs for a short time but does not complete recovery

Problem:

Tank valves are closed

Solution:

Open both valves and be sure hoses are properly
connected to the tank

Problem:

Manifold valves are closed

Solution:

Open both valves

Runs but will not shut off

Problem:

Oil drain valve is open

Solution:

Close the oil drain valve

Problem:

There is a leak in the A/C-R system

Solution:

Locate and repair all system leaks

Problem:

Hoses are not properly connected to the vehicle

Solution:

Check hose connections

Problem:

Oil return solenoid is open

Solution:

Replace the oil return solenoid