Model 178002K/178012K Recovery/Recycling/Recharging Unit

41

Troubleshooting

Problem:

Tank valves are closed

Solution:

Open both valves and be sure hoses are properly
connected to the tank and the unit

EVACUATION OPERATION

Vacuum pump will not start

Problem:

Vacuum pump is unplugged from unit

Solution:

Plug the pump into a power source

Problem:

Power cord is not plugged in or there is no power at plug

Solution:

Check circuit for power

Problem:

The pressure in the A/C-R system is too high

Solution:

Recover the remaining A/C-R system charge

Problem:

“U-HI” message on digital display

Solution:

Recover all refrigerant before pulling a vacuum

Problem:

Vacuum time not entered

Solution:

Program the required time for vacuum

Vacuum pump runs but low side gauge does not register an
appropriate vacuum

Problem:

Low side valve is closed

Solution:

Open the low side valve

Problem:

Pump oil is contaminated

Solution:

Flush and change the vacuum pump oil

Problem:

Hose connection is loose or manifold is leaking

Solution:

Check connections

CLEARING OPERATION

“CLR” displays on screen

Problem:

Pressing HOLD/CONT does not clear the display

Solution:

Slide the lockout panel on the back of the unit to expose the fittings for the correct refrigerant
type, connect the appropriate hoses and perform a clearing procedure (see Step 12 in Set Up
Instructions
)