CHECKING FOR LEAKS

Every three months, or as specified by local or state laws, you should check your unit for
leaks. As with any mechanical equipment, general use, moving the unit and vibration can
cause fittings to loosen.

1. Turn off the MAIN POWER switch, and disconnect the power cord from the

outlet.

2. Remove the front shroud by removing the 16 threaded screws on the front of the

unit.

3. Use a leak detector to probe all fitting connections for refrigerant leaks. Tighten

fittings if a leak is indicated.

4. Replace the shroud.

Diagram of Threaded Screws

Threaded

Screws

Important:

Inspect the unit
periodically for
leaks. The manu-
facturer does not
reimburse for
lost refrigerant!