USING DISPLAY CODES

134A

R-134a; indicates R-134a automotive refrigerant requiring

1

/

2

” Acme

fittings.

Add

Add refrigerant to the tank before starting charging procedures.

CAL

The scale is out of calibration; see Calibrating the Scale.

Check
Refrigerant

Tank has six (6) pounds or less of refrigerant; charging will not activate.

CH-F

Change compressor oil and filter/drier; 200 pounds of refrigerant has
been recovered since the last change.

CH-P

A/C-R system pressure is low; prevents pulling air into the unit from a
leaky system.

CL-c

Clearing complete; indicates that the first stage of the clearing process is
complete.

CL-L

The low side clearing routine is in progress; this occurs when you press
RECOVER and can last up to four minutes.

Clr

Self-clearing; if this message is displayed, the unit is in the self-clearing
process.

CON

The vacuum pump will run continuously; press SHIFT/RESET to stop.

CONT

Continue; indicates that unit pressure has equalized during the first stage
of the clearing process.

CPL

Complete; the current procedure is finished.

door

(Flashes) The unit has been cleared and you can now select a door
position. Slide the refrigerant lockout panel (located on the back of the
unit, top left corner) to expose the fittings for the selected refrigerant
type.