2 how to acquire the stopper interfering point – IAI America IX-NNN12040 User Manual

Page 71

Advertising
background image

4. Maintenance inspection

65

4.4.2 How to Acquire the Stopper Interfering Point

In the following case, conduct “Stopper pressing position acquirement

(Note 1)

” before having the

absolute reset.

x

When the absolute reset cannot be performed in the direction of the stopper interfering

movement with the initial posture at the delivery from the factory due to such reasons as

interference to the peripheral equipment

x

There was a change in the stopper position due to such reasons as a removal of the

stopper of the vertical axis

Note 1 In case that the absolute reset cannot be performed with the stopper pressing

movement direction of the initial posture set at the delivery due to such as

interference with peripheral devices, change the setting to the initial posture of the

left arm system (stopper pressing direction on opposite side) and conduct the

stopper pressing position acquirement.


















(Reference)



















Initial Posture of Left Arm System (Opposite interfering direction)

Arm 2 =

Negative Coordinate

Direction

Arm 1 =

Positive Coordinate

Direction

The direction of interfering is as shown below in the initial setting at the delivery from the

factory.

Arm 2 =

Positive Coordinate

Direction

Arm 1 =

Negative Coordinate

Direction

Vertical Axis =

Negative Coordinate Direction

Rotation Axis =

Negative Coordinate Direction

Initial Posture of Right Arm System

Advertising