13. Inspection/Maintenance

(3) Unplug the BAT connector and connect a new battery.

x After removing each battery, set a new battery within 1 to 2 minutes (reference).

x If replacement takes a longer time, multi-rotation data will be cleared and an absolute reset will become

necessary.

x Replace the batteries axis by axis. If all batteries are replaced at once, the replacement may not finish within

the time limit.

(4) Store the battery in the battery holder.

(5) Secure the cover (base) using the hexagonal countersunk head bolts (4 pcs). (Tightening torque: 0.8 N

‚m)

x When installing the cover (base), be careful not to pinch the internal wiring.