IAI America IX-NNN1805 User Manual

Page 90

Advertising
background image

84

13. Inspection/Maintenance

(6) Click the “Servo-OFF” button.

Servo OFF

(7) Press the emergency-stop switch.
(8) Affix the rotational axis at the reference position by setting the plate and pin of the adjustment jig as

illustrated below.

x Set the jig after confirming that the emergency-stop switch is pressed.

x Set the jigs by using the positioning mark as a reference.

x Make sure the top surface of the stopper roughly matches in height with the bottom surface of arm 2.

Reference Posture for Arm Length 120

Turn the rotational axis
until it makes contact, to
eliminate any gap.

Set the plate so that the

‡3 hole comes to

the side opposite the D-cut surface.

(Down view).

Pin, absolute reset jig

Plate, absolute reset jig

Advertising
This manual is related to the following products: