13. Inspection/Maintenance

Reference Posture for Arm Length 150/180

z Always press the emergency-stop switch before setting an adjustment jig. Failure to do so may cause the

robot to malfunction and result in a serious accident.

z Pay attention to the orientation of the side of the plate jig that comes in contact with the D-cut surface.

Turn the rotational axis
until it makes contact, to
eliminate any gap.

Set the plate so that the

‡3 hole comes to

the side opposite the D-cut surface.

(Down view).

Plate, absolute reset jig

Pin, absolute reset jig