Program construction for operation, 1 sel command – IAI America XSEL-S User Manual

Page 100

Advertising
background image

6. Program Construction for Operation

94

6. Program Construction for Operation

6.1

SEL Command

Vision System I/F Function supports 2 types of the dedicated SEL commands listed below.

SEL Command

Description

SLVS

Selects Vision System I/F to be used

GTVD

Acquires the captured image data (Stores the work data to the
variables and positions)

* [XSEL-P/Q]

Applicable PC soft version: V7.06.08.00 or later (Except for Cognex In-Sight EZ110)
Applicable PC soft version: V7.07.08.00 or later (For EZ-110XL)

[XSEL-R/S]

Applicable PC soft version: V9.0.0.0 or later (Except for Cognex In-Sight EZ110)
Applicable PC soft version: V9.0.0.0 or later (For EZ-110XL)

6.1.1 SLVS (Select Vision System I/F) Command

z

SLVS (Select Vision System)

Command and Declaration

Expansion

Condition

(LD,A,O,AB,OB)

Input Condition

(I/O • Flag)

Command and

Declaration

Operation 1

Operation 2

Output section

(Output • Flag)

Free

Free

SLVS

Select Vision

System I/F

(Timeout time)

CC

[Function] Select whether using Vision System I/F in this command (GTVD Command).

Operation 1 : Select Vision System I/F

0 : To use Vision System I/F
1 : Not to use Vision System I/F

Operation 2 : Operation 1=Invalid when set to “0”.······· Prohibited

Operation 1=Except for “0”·······Timeout time (sec) when GTVD Command is

executed
The setting range for the timeout time is from
0.01 to 99.00 sec.
When no indication (Operation 2 = blank) is
defined, the timeout setting is not established
and is set to no limitation.

Advertising
This manual is related to the following products: