Error treatment, 1 common errors for all vision systems – IAI America XSEL-S User Manual

Page 106

Advertising
background image

7. Error

T

reatment

100

7. Error Treatment

7.1

Common Errors for All Vision Systems

Following explains the details of the errors and how to deal with it when an error number is
displayed.
Refer to the corresponding error number to have an appropriate treatment when an error is issued.
(Note) Refer to Section 7.2 if an error is generated while in the simple (dedicated) calibration with

using EX-110XL.

Error No.

415

Name

Unsupported Identification Code Received Error (Tracking and Vision System I/F data
communication)

Description

An error is detected in the identification code of a message received from the vision
system.

Treatment

Identification code is a fixed value.
8.1 Check and correct the communication format settings.

Error No.

416

Name

Received Message Error(Tracking and Vision System I/F data communication)

Description

An error is detected in the message received from the vision system.
Select “Monitor” o “Error Detail” from the menu in X-SEL PC Software.
The cause of the error is displayed in Info 1 and Info 2 in Error Detail.
Check the message settings on the Vision System side following the table below.

Info1

Info2

Cause

Treatment Detail

1h

-

Header

The received message header is wrong. Check the
following parameter settings.
* The setting differs depending on the vision system

supplier.

x

I/O Parameter No.352, Bits 0 to 7: when set to 0 or 1

o

Check the settings in I/O Parameter No.353, Bits 8 to

15. (Cognex : 3C

H

, OMRON : 39

H

)

x

I/O Parameter No.352, Bits 2 to 7: when set to 0

o

Check the settings in I/O Parameter No.353, Bits 16

to 31. (Keyence : 5431

H

)

2h

-

Identification
Code

There is no identification code in the received
message, or a character other than 0 to 9 (ASCII value)
is set to the identification code.
Check the identification code setting for the message.
[Refer to 8.1 Communication Format Setting Values]

3h

-

Work
piece

There is no work piece quantity data in the received
message, or a character other than 0 to 9 (ASCII value)
is set to the work piece quantity.
Check the work piece quantity data setting for the
message.
[Refer to 8.1 Communication Format Setting Values]

Treatment

Advertising
This manual is related to the following products: