Work flow before operation start, 1 starting procedures, Check of packed items – IAI America XSEL-S User Manual

Page 16: Installation and wiring, Power supply and alarm check, Check of safety circuit actuator setting, Power-up and operation check

Advertising
background image

2. W

ork Flow before Operation Start

10

2. Work Flow before Operation Start

Note

Make sure to have the settings of the vision system such as the work detection setting and
communication setting done before having the vision system I/F function settings.

2.1

Starting Procedures

No

No

No

Yes

Check of Packed Items

Are there all the delivered items?

Do you have all the equipment listed in Section 2.2 that needs to be

prepared beforehand?

Yes

Yes

Yes

Yes

Yes

Installation and Wiring

Have the actuator and encoder installed and connected following the instructions in XSEL Controller Instruction

Manual, Actuator Instruction Manual and this manual (see Section 4).

Are the frame grounding (FG) and protection earthing (PE) conducted?

Has the noise countermeasure been taken?

Power Supply and Alarm Check

Connect the PC, put AUTO/MANU switch to “MANU” side and

turn the power on.

Is the status display showing “rdy” ?

Check of Safety Circuit

Actuator Setting

Check that the emergency stop circuit (or motor drive power cutoff

circuit) operates normally to turn off the servo.

Vision System I/F Function Setting (Refer to Section 5)

The setting details differ depending if the camera is mounted to the robot or not.

Creating Program (Refer to Section 6)

Create a program based on SEL program construction capacity.

Power-up and Operation Check

Have the program run to check the sensor input, axis data from the camera and tracking position.

Have an appropriate treatment following

the content of the status display.

[Refer to the trouble shootings in Instruc-

tion Manuals for XSEL Controller and PC

Software.]

No

Is the motor cable connected?

No

Contact the sales shop.

Connect the motor cable.

Check the emergency stop circuit.

Check the alarm content on the PC to

have an appropriate treatment if an

alarm is generated.

Write the target position to the position table.

Press the SV button in the button display for each axis in the PC

software to turn the servo on.

After the servo is on, press the HM button in the button display for

each axis to conduct a home-return operation.

Did the servo turn on and home without error?

Now, the operation adjustment is complete.
Conduct an adjustment by the system.

Advertising