2 general-purpose rs232c port – IAI America XSEL-S User Manual

Page 123

Advertising
background image

8.
Appendix

117

8.2

General-purpose RS232C Port

Vision System

RS-232C

X-SEL Controller

RS232C Connector Specifications
Applicable Connector

D-sub 9-pin (DTE)

XM2C-0942-502L (OMRON)

Connector Name

S1/S2

Max. Connectable
Distance

10m

at 38400bps

Number of Channels

2

General-purpose RS232C Port Connectors 1
and 2

Channel 2

Channel 1

Pin No. Direction Signal Name

Description

1

In

(CD)

(Carrier Detection : Not Used)

2

In

RD

Received Data (RXD)

3

Out

SD

Sent Data (TXD)

4

Out

ER

Equipment Ready (DTR)

5

In

SG

Signal Ground

6

In

DR

Data-Set Ready (DSR)

7

Out

(RS)

(Request for Sending (RTS) : Not Used)

8

In

(CS)

(Sending Available (CTS) : Not Used)

Terminal

Assignment

9

Out

GV or NC

Channel 1 : NC
Channel 2 : GV (power supply to the converter

unit) when RC Gateway function is

used

NC when RC Gateway function is

not used.

Advertising