5-8

X16
X17

24V DC

When not using the start switch
(

Auto start)

X16
X17

24V DC

When not detecting the welding of start
switch
(

Manual start)

X16
X17

24V DC

When detecting the welding of start
switch
(

Control start)

S7

S7

X0

X1

T0

T1

X12

T12

X13

T13

When connecting multiple emergency stop switches in
series

X0

X1

T0

T1

X12

T12

X13

T13

When not using some inputs

NOTE: Applicable safety performance is dependnt on
each system configuration.

Note: In the case of using a spring lock type safety switch for the safety input of SafetyOne, if
the solenoid output of SafetyOne is connected to solenoid power terminal of the safety switch
directly, the start condition cannot be established due to the safety input stays in the OFF state.
In this case, connect the switch or other equipment to solenoid output of SafetyOne, and turn
off the operation of the solenoid for lock control.