31 operation example (logic 4), Warning – IDEC FS1A Controller User Manual

Page 72

Advertising
background image

5-31

Operation example (Logic 4)

Contactor/
safety relay ON

Machine running

Muting lamp OFF

Safety light
curtain
(

PNP)

Muting sensor
(

PNP)

Emergency stop
switch

Safety light
curtain
(

PNP)

Muting sensor
(

PNP)

(Note) Make sure that the intersection of optical axes is within the hazardous area.

Contactor/
safety relay ON

Machine running

Muting lamp ON

Shade!

Machine stop

Shade!

Contactor/
safety relay OFF

Muting lamp OFF

Warning

When installing light curtains and muting sensors, ensure safety by referring to

IEC TS 62046 technical documents.

・

Emergency stop switch is released.

and

・

Invasions through opening are not detected.

・

Start input is ON

・

Safety outputs are ON.

・

Invasion through opening is detected

while muting sensors are shaded.

・

Safety outputs are ON.

・

Muting lamp outputs are ON.

・

Safety outputs are ON.

・

Invasion through opening is detected

while muting sensors are not shaded.

・

Safety outputs are OFF.

・

Safety outputs are ON.

Safety
light curtain

Muting lamp

Muting sensors

Hazardous Area

Work Objec t

(Note)

Muting lamp

Muting sensor beam blocked
Light curtain beams blocked

Hazardous Area

Light curtain blocked

Light curtain beams blocked

Light curtain beams blocked

Hazardous Area

Advertising