41 operation example (logic 5) – IDEC FS1A Controller User Manual

Page 82

Advertising
background image

5-41

Operation example (Logic 5)

Open!

Open!

Open!

Close

Close

Close

Interlock switch A

Interlock
switch B

Interlock switch A
(

Single contact )

Interlock switch B
(

Single contact)

Interlock switch A
(

Single contact )

Interlock switch B
(

Single contact )

Contact ON

(

Door is closed)

Contact OFF

(

Door is opened)

Input monitor error detection time is 0.5s.

Input monitor error detection time is infinite.

Contact ON

(

Door is closed)

safety input device is checked.

Input monitor error
detection time is
exceeded.

Input monitor error is detected.

As the result of input monitor
error detection time is infinite,
the error is not detected.
Safety output is turned off.

STOP

Production machinery

In case of Logic 1

In case of Logic 5

∞

Contact OFF

(

Door is opened)

Contact OFF

(

Door is opened)

Contact OFF

(

Door is opened)

Contact ON

(

Door is closed)

Contact ON

(

Door is closed)

The syncronizations of each

Contactor/
safety relay OFF

Press!

Open!

or

Machine stop

Solenoid output ON

Guard lock release

・

Emergency stop switch is pressed

or

・

Movable guard is opened.

(Contacts of 1 of

the

interlock switches

are OFF)

・

Safety outputs are OFF.

・

Solenoid outputs are ON.

・

Safety outputs are ON.