Launching Your Analyzer

 Teledyne  LeCroy

The software checks SFP speed for functional ports. For example, if you set the port 
configuration to AGE10_AAGE10_AFC_AFC, the software checks if SFP supports 10G on 
ports 1, 2 and 3, 4 and 16G on port 5,6 and 7, 8. If the software finds any mismatch 
between the given port configuration and SFPs, it displays a warning message describing 
the issues, but does not stop the Analyzer and/or Jammer. 

1.5

Launching Your Analyzer

To launch the software, double‐click the

 

Ethernet Protocol Suite

 

Icon in the Program 

Manager Window.

Click OK to display the software.

1.5.1

Operating in Simulation Mode

The system operates in Simulation Mode by default if the software detects no hardware. 
However, you can operate in Simulation Mode directly, without installing the Analyzer 
hardware. 

The Analyzer software launches and displays the appropriate tool bar, but with the 
limitation that the Analyzer operates only on static, previously captured, bus data.

Limitations

Simulation Mode lets you try all of the available functions, but the system is not 
capturing any real data and is displaying only pre‐captured results.

1.5.2

Using the Software

The SierraNet M168 application has protocol analysis software to capture data, trigger on 
Events, and save. Easy Mode allows standard Trigger and Data capture. Advanced Mode 
allows you to program custom triggering in and out, capturing, state jumps, and timers. 
(

See “Protocol Analysis” on page 35.

)

1.5.3

Add Device to Project

After you start the software, select File > New Project to open Add Device to Project 
dialog. The following Add Device to Project dialog displays (see 

Figure 1.11 on page 22

). 

The colors in the ‘Location’ column mean the following:

Red: Firmware and/or BusEngine components need to be updated to the latest 
version

Light Blue: The device is ready to be connected.

Yellow: The device is locked.

Green: The software is connected and ready to run

Select a device with “Ready to connect” status.

If the device supports more than one protocol, select the desired protocols from the 
drop‐down list in the Port column. 

Select the port configuration from the Link Assignment column.