3 connection management (sas only) – Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 190

Teledyne LeCroy
Target and Device Emulation
188
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
Figure 2.180: SAS: Identify Error Setting Dialog
Sending Identify Frame
Check the Send option button, then specify the number of Identify frames to send (and a
delay, if needed).
Not to send Identify frames, check the Do not send identify frames option button.
Frame Type Error
Check this to send a Frame Type error.
Frame Length Error
Check Frame Length error and enter the number of DWORDs in the corresponding text
box.
SOAF, EOAF and CRC
Check any or all and check the criteria for introduction.
Code violation and Disparity
Check either or both and specify DWORD offset and Number of DWORDs in the
corresponding text boxes.
2.6.3
Connection Management (SAS only)
Click the Connection Management icon in the Errors window to display the Connection
Management Setting dialog (see
).