Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 396

Teledyne LeCroy
Scenario Batch Files
392
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
Example
Label3: WaitForStop(0x83456, 2, 100))
Run (ox01267," Inject CRC000", 4)
Goto Label7
Note:
You can use a Label and a Goto Label to make loops. First make the label, then make Goto Label.
The Command Parameters window shows only enabled Labels. Labels are disabled by default
and are in gray color. To enable them, click them to make purple color.
Run
Runs the scenario on hardware on specified ports. If you call this command for the first
time and the scenario was not assigned to the hardware and ports before, the scenario is
assigned to specified hardware and ports and then scenario runs on the hardware.
Format
Run(Serial Number, Scenario Name, Target Port)