Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 388

Teledyne LeCroy
Creating a Sequence
384
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
TABLE 4.12: Example 9: Logic of Sequence 0
1. Click the New Scenario button in the main library or one of the device libraries. In
the Scenario Properties dialog, enter the scenario name, description, and direction
of traffic change.
2. As in previous examples, create the five states for this sequence.
State
Description
Wait for Align (0)
When an Align (0) is received, go to Wait for Align (1).
Wait for Align (1)
If an Align (1) is received next, go to Wait for Align (2);
otherwise, replace primitive with Align (1) and go to Indicate
Error.
Wait for Align (2)
If an Align (2) is received next, go to Wait for Align (3);
otherwise, replace primitive with Align (2) and go to Indicate
Error.
Wait for Align (3)
If an Align (3) is received next, restart test;
otherwise, replace primitive with Align (3) and go to Indicate
Error.
Indicate Error
Indicate error and restart test.