Note:
The command code and feature set are not the only parameters that describe an
ATA command. For parameters such as LBA and sector count, use the ATA Command Pattern
dialog.
Data Pattern
Double‐click Data Pattern in the Patterns window of the Trigger dialog to open the Data
Pattern dialog.
Figure 2.51: SAS: Data Pattern Dialog
SAS vs. SATA: SATA Dialog shows Port at the top and does not show SSP or STP.
Define the data pattern for triggering and click OK.
Note:
When entering the data pattern in the “Data” section of this screen, if you are reading the data
pattern from a recorded trace, you must reverse the order of the bytes listed for each DWORD
entered. For example, if you want to trigger on “00 01 02 03” (as displayed in the trace), you
must enter this DWORD pattern as “03 02 01 00”.