NOTE:

The DC power supply connector (plug) for GP-4200 Series / GP-4300 Series

/ GP-4400 Series is PFXZCBCNDC1 (manufactured by Pro-face).
The DC power supply connector (plug) for GP-4500 Series / GP-4600 Series is
PFXZCBCNDC2 (manufactured by Pro-face).

(The above items are manufactured by Phoenix Contact.)

How to connect the DC Power Cord

Connection

Wire

+

24 Vdc

-

0 Vdc

FG

Grounded terminal connected to the panel chassis.

Recommended Driver

SZS 0.6x3.5 (1205053)

Recommended Pin Terminals

3201288 AI 0,75-10 GY
3200182 AI 1 -10 RD
3200195 AI 1,5 -10 BK
3202533 AI 2,5 -10 BU

Recommended Pin Terminal Crimp
Tool

CRIMPFOX 6

FG

-

+

Step

Action

1

Confirm the power cord is not connected to the power supply.

2

Check the rated voltage and remove the “DC24V” sticker on the DC power
supply connector.

3

Remove 10 mm (0.39 in.) of the vinyl membrane off the ends of the power cord
wires.

4

If using stranded wire, twist the ends. Tinning the ends with solder reduces risk
of fraying and ensures good electrical transfer.

5

Push the Opening button with a small and flat screwdriver to open the desired
pin hole.