2

Attach the installation gaskets to the panel.
Installation gaskets are included for the standard mount orientation and for the
flat mount orientation.

Peel off the removable paper layer, and then attach the adhesive surface to the
rear surface of the resin plate as shown in the figure. Follow the cross-section
of the panel cut and attach the adhesive surface on top of the installation gas-
ket so that the adhesive surface sticks out by approximately 3 mm (0.12 in.)
past its adjacent adhesive surface.

a) Boss when attaching installation brackets at the top and bottom surfaces of

the GP unit

b) Boss when attaching installation brackets on either side of the GP unit

Note:

z

Be sure to use the included installation gaskets.

z

Due to the installation gasket properties, do not pull on the installation
gaskets while you attach them. Doing so may cause the installation gaskets
to be embedded in the installation brackets.

z

If the installation gaskets are used for a long time, the gaskets may be
damaged or dirt may affix to the gaskets, which may cause their
effectiveness to decrease. Replace the installation gaskets periodically.

z

The appropriate length of the installation gasket is as follows;

(1) When the GP unit installing horizontally
(2) When the GP unit installing vertically

Step

Procedure Details











1) The installation gakets for Flat mount
2) The installation gakets for Standard mount

D

D

E

E

E

E

D

D

Rear surface of the panel

Cross-section
of the panel

mm(in.)

(dimensional tolerance:

±1mm [0.04 in.])

Standard Mount

Flat Mount

A

B

A

B

PFXGP4301TADR

97 [3.82]

126 [4.96]

116 [4.57]

150 [5.91]

PFXGP4401TADR

125 [4.92]

142 [5.59]

142 [5.59]

182 [7.17]

PFXGP4501TADR

169 [6.65]

222 [8.74]

195 [7.68]

248 [9.76]

PFXGP4601TADR

195 [7.68]

257 [10.12]

222 [8.74]

297 [11.69]



$



$

$

$

%

%

%

%

Advertising