70

Memory, Clock, and Touch Panel

Memory

*1

Capacity available for user application (internal memory).

*2

Up to 60,000 steps can be converted in software. However, this reduces

application memory capacity for screen data by 1 MB.

NOTE:

z

When the message "RAAA051 Low battery" is displayed on the GP-4301TW,
supply power to the GP unit and fully charge the battery. In 24 hours the battery
charges to a level that allows backup operation. Completing a full charge requires
about 120 hours (5 days).

z

The lithium battery’s lifetime is: 10 years when the battery’s ambient temperature
is 40 °C (104 °F) or less, 4.1 years when the battery’s ambient temperature is 50

°C (122 °F) or less, and 1.5 years when the battery’s ambient temperature is 60

°C (140 °F) or less.
When used for backup:
Approximately 100 days, with a fully charged battery.
Approximately 6 days, with a half-charged battery.

GP-4301T / GP-4303T

GP-4301TW

Application Memory

*1

FLASH EPROM 16 MB
(including the logic
program area)

FLASH EPROM 8 MB
(including the logic
program area)

Logic Program Area

FLASH EPROM 132 KB (Equivalent to 15,000
steps

*2

)

Font Area

FLASH EPROM 8 MB (when this limit exceeded,
uses application memory)

Data Backup

SRAM 320 KB
(Replaceable lithium
battery for data backup)

SRAM 128 KB
(Rechargeable lithium
battery for data backup)

Variable Area

SRAM 64 KB
(Replaceable Lithium
battery for retentive
variables)

None