Wiring, Watlow ez-zone, Chapter 2 install and wire – Watlow EZ-ZONE ST User Manual

Page 11: Status indicator light

Advertising
background image

Watlow EZ-ZONE

®

ST

9

Chapter 2 Install and Wire

+

+

+

S1

S2

S3

S1

S3

+

Thermocouple
(Input 2)

Process

0 to 20 mA

(Input 2)

N.O. (Output 3)

N.C. (Output 3)

common (Output 3)

N.O. (Output 4)

contactor (Coil 1)

Contactor

Coil 1

Contactor

Coil 2

ST_

B - _ _ _ _ - _ _ _ _ (no limit)

ST_

L - _ _ _ _ - _ _ _ _ (with limit)

common (R

UI)

T-/R- (R

UI)

T+/R+ (R

UI)

- common (Digital I/O)

+ Digital Input 6 or Output 6

+ Digital Input 5 or Output 5

ST_ _ - _ _

A _ - _ _ _ _

Remote User Interface (RUI)

common (Modb

us R

TU)

T-/R- (Modb

us R

TU)

T+/R+ (Modb

us R

TU)

- common (Digital I/O)

+ Digital Input 6 or Output 6

+ Digital Input 5 or Output 5

ST_ _ - _ _

M _ - _ _ _ _

Modbus RTU on EIA-485

Limit

Address

Selection

fuse

load

S1

S2

S3

+

S1

S3

2-wire

RTD

(Input 1)

3-wire

RTD

(Input 1)

Thermocouple
(Input 1)

Process

0 to 20 mA

(Input 1)

Process

0 to 10V

Î (dc)

0 to 50mV

Î (dc)

(Input 1)

N.O.

(Output 2)

common

(Output 2)

Controller

+

2-wire

RTD

(Input 2)

3-wire

RTD

(Input 2)

98

99

CF

CD

CE

B5

D6

D5

L2

K2

T1

S1

R1

L2

K2

T1

S1

R1

98

99

CC

C

A

CB

B5

D6

D5

1 2 3 4

ON

L3

K3

J3

A1

L4

T2

S2

R2

L2

K2

T1

S1

R1

L2

K2

T1

S1

R1

L2

K2

T1

S1

R1

L2

K2

T1

S1

R1

L3

K3

J3

A1

L4

T2

S2

R2

L3

K3

J3

A1

L4

T2

S2

R2

L3

K3

J3

A1

L4

T2

S2

R2

L3

K3

J3

A1

L4

T2

S2

R2

neutral

hot

fuse

fuse

earth

ground

1

6

3

4

A1

A2

2

5

EZ-ZONE™ ST

Patent Pending

Integrated

Control Loop

1 2

3

4

ON

L

IM

IT

O

U

T

3

S

S

R

S

TA

T

U

S

O

U

T

2

L

IM

IT

O

U

T

3

S

S

R

S

TA

T

U

S

O

U

T

2

hot

hot

Process

0 to 10V

Î (dc)

0 to 50mV

Î (dc)

(Input 2)

Power Supply

Power Supply

fuse

fuse

Output 1 (SSR)

Wiring

with a contactor (ST _ _ - (B or F) _ _ _ - _ _ _ _)

Ó

WARNING: Use National Electric
(NEC) or other country-specific
standard wiring and safety prac-
tices when wiring and connecting
this controller to a power source
and to electrical sensors or pe-
ripheral devices . Failure to do so
may result in damage to equip-
ment and property, and/or injury
or loss of life .

ç

WARNING: If high voltage is applied to a

low-voltage controller, irreversible damage

will occur .
Note:

Terminals L4 and A1 on the limit connector

are jumpered at the factory to complete the

contactor circuit . Additional switches may
be wired in series to the terminals .
Note:
Use the contactor with a minimum load of
100 watts .

STATUS Indicator Light

Flashing green indicates the controller is run-

ning with no input errors .
Flashing red indicates an input error .
No flashing indicates that the controller is not

functioning .

CAUTION: Always mount the controller as

shown, with the heat-sink fins aligned verti-

cally .
Note:
The control common terminal and the digital

common terminal are referenced to different

voltages and must remain isolated .

Note:

A2 is connected internally to terminal 98 .

A1 is connected internally to the contac-

tor coil . The other side of the coil is con-

nected to terminal 99 .