EZ-ZONE ST Replacement Modules

S T R C

-

0 __ __ __

-

__ __ __ __

STRC-0 (Series ST Replacement Control Module)
- Output 1 is dedicated to controlling the internal Solid-State Relay.
- Includes 1 universal input and 2 outputs for heat, cool or alarm
Output 2, Digital I/O and Current Measurement
K

0.5 A solid-state relay

B

0.5 A solid-state relay with 2 digital i/o points

P

0.5 A solid-state relay with current measurement

E

0.5 A solid-state relay with 2 digital i/o points and current measurement

H

5 A mechanical relay form A

D

5 A mechanical relay form A, 2 digital i/o points

J

5 A mechanical relay form A, current measurement

C

5 A mechanical relay form A, 2 digital i/o points, current measurement

Integrated Limit Controller

1 universal input and 2 outputs

A

None

L

Limit control module (output 3, 5A, Form C mech. relay; out. 4, 2A, Form A mech. relay)

B

Terminal block access to mechanical contactor coil contacts

Power Supply for Mechanical Contactor

L - For use with mechanical contactor options AL, B1 and F1
H - For use with mechanical contactor options AH, B2, B3, F2 and F3

L

Low voltage power supply 24 to 28V

(ac/dc)

H

High voltage power supply 100 to 240V

(ac/dc)

Communications
A

Standard software to connect to pc software, remote user interface (RUI) and other EZ-ZONE devices

M

Modbus™ RTU communication port to connect to non-ST products

Firmware

Options

Original Model Includes a

Phase Angle SSR

SSR = M, N, P, R, S or T

Original Model Includes a

75A Heat Sink

Heat Sink = D, E or F

Original Model Includes

Profile Ramp & Soak

Firmware = P

B =

No

No

No

C =

No

No

Yes

D =

No

Yes

No

E =

Yes

No

No

F =

Yes

Yes

No

G =

No

Yes

Yes

H =

Yes

No

Yes

J =

Yes

Yes

Yes

Customization (logo, parameters, hardware, firmware)

AA

Standard

XX

{letters to be determined, consult factory}