Chapter 5: profiling page, Profiling parameters, How to start a profile – Watlow EZ-ZONE ST User Manual

Page 56

Advertising
background image

Watlow EZ-ZONE

®

ST

•

54

•

Chapter 5 Profile Page

Chapter 5: Profiling Page

5

The Profiling Page allows you to enter your ramp

and soak profile information.
To go to the Profiling Page from the Home Page,

press the Advance Key

‰

for three seconds, until

[ProF]

appears in the lower display and the profile

number appears in the upper display. Press the Up
¿

or Down ¯ key to change to another profile.

• Press the Advance Key

‰

to move to the selected

profile's first step.

• Press the Up ¿ or Down ¯ keys to move

through the steps.

• Press the Advance Key

‰

to move through the

selected step's settings.

• Press the Up ¿ or Down ¯ keys to change the

step's settings.

• Press the Infinity Key ˆ at any time to return

to the step number prompt.

• Press the Infinity Key ˆ again to return to the

profile number prompt.

• From any point press and hold the Infinity Key

ˆ

for two seconds to return to the Home Page.

Note:

Changes made to profile parameters in the Profiling Pages will be

saved and will also have an immediate impact on the running pro

file .

Some parameters in the Profile Status Menu can be

changed for the currently running profile, but should only

be changed by knowledgeable personnel and with caution .

Changing parameters via the Profile Status Menu will not

change the stored profile but will have an immediate im-

pact on the profile that is running .

How to Start a Profile

After defining the profile follow the steps below to

run the profile:
1. From the Home Page push the Advance Key

‰

repeatedly until Profile Start [P;St1] appears in

the lower display.

2. Use the Up ¿ or Down ¯ key to choose the file

or step number within a profile where you want

the profile to begin running.

3. Press the Advance Key

‰

. This takes you to Pro-

file Action [P;AC1], where you can select the ap-

propriate action.

• [none] No action
• [ProF] Begin execution from first step of the

specified profile number, whether it exists or

not.

• [PAUS] Pause the currently running profile.
• [rESU] Resume running the profile from the

previously paused step.

• [`End] End the profile.
• [StEP] Begin running the profile from the spec-

ified step number.

Note:

Avoid continuous writes within loops . Excessive writes to EEPROM

will cause premature EEPROM failure . The EEPROM is rated for

1,000,000 writes . Navigate to Setup Page under the Com menu

and set prompt Non-volatile Save

[`nU;S] to No .

Profiling Parameters

[prof]

Profile

[``p1]

to [``p4]

[``p1]

Step 1 (to 10)

[``p2] Step 11 (to 20)

[``p3] Step 21 (to 30)

[``p4] Step 31 (to 40)
[S;typ]

Step Type

[t;SP1]

Target Set Point Loop 1

[hoUr]

Hours

[Min]

Minutes

[`SEC]

Seconds

[RATE]

Rate

[W;P1]

Wait For Process 1

[WE;1]

Wait Event 1

[WE;2]

Wait Event 2

[``JS]

Jump Step

[``JC]

Jump Count

[`EnD] End Type

[Ent1] Event 1

[Ent2] Event 2

Note:

This page appears only if 10

th

digit of part number is P

ST _ _ - _ _ _ _ - _ P _ _

Advertising