Users Manual

IC-R-II

19

CONNECT

The vertical pane in each Properties window provides for loudspeaker identification and selected control features. See below for details.

Status Indicators: The Thermal, Peak and Fail indicators above the output meter provide critical information on the array’s status. The

Peak indicator will flash yellow or red whenever the device’s peak limiter is triggered. It’s normal for the indicator to flash occasionally if

the loudspeaker is being used close to its rated output. Flashing frequently is a sign that the system volume needs to be turned down. The

Thermal indicator will start to flash yellow as the amplifier temperature approaches a preset level and will turn red if the temperature contin-

ues to increase as a warning the amplifier is about to be shut down. The Fail indicator glows red when the amplifier has been shut down by

the protective circuitry. Heat related shutdowns will reset automatically after the amplifier cools down to a safe temperature.

As a further protective measure, the amplifier’s gain will gradually be reduced in response to overheating and/or to high an input level.

However, it’s best to manually reduce the input signal level (overall system volume) in response to distress signals.

Power On/Standby Button: Note that the Power On/Standby button will not show while operating in the virtual mode. It appears only

when associated with an actual array.

Loudspeakers model number or name

Input signal level bar graph; “0” indicates

the onset of input clipping. Analog inputs

clip at +12 dBu without the 10 dB input

pad, +24 dBu with the pad.

Volume control slider; adjust by grabbing

slider with mouse or by using up/down

arrows. Settings adjustable from “0” to -50

in 1 dB steps, then to -100 dB in one step;

settings below -8 dB prevent the loud-

speaker from reaching full output.

Inv. button inverts the input signal polarity;

glows green when signal is inverted. Use

with caution.

Amplifier temperature indicator and

bar graph.

Save button

Reads Save whenever a change is

made as a reminder of the need to save

changes.

Text fields for entering a name for the

loudspeaker and listing its location.

Press Wink with Light button to turn the

loudspeaker’s wink light on and off to aid in

identifying the loudspeaker and its location.

Press Wink with Audio to send a Tone

signal or Pink Noise to the loudspeaker.

Output status indicators for each amplifier.

See Status Indicators below for details.

Output bar graph. “0” represents the

maximum uncompressed output level;

positive values indicate how far the signal

is overshooting into limiting; negative

values indicate the amount of headroom

left before the onset of limiting.

Mute button mutes the entire loudspeaker.

Press to restart the loudspeakers DSP in

the event of a malfunction.

Power On/Standby button. Turns ampli-

fier On or places it in Standby. Turning

AC power to the Array On and Off is a

separate operation.

Loudspeakers DSP sample rate (48 kHz or

96 kHz). See Appendix lll for more details.