Renkus-Heinz IC32-R-II User Manual

Page 53

Advertising
background image

APPENDIX II: RHAON Block Diagrams

Serial Digital (AES3 aka AES/EBU)

The block diagram below shows a RHAON system using digital audio distribution in the AES3 format along with RHAON loudspeaker

control and monitoring. Notice that the wiring loops from loudspeaker to loudspeaker just as it does in analog distribution. The digital audio

distribution line is conventional twisted pair shielded digital audio cable, Beldon 1800B or 1800F or equivalent.

Notes

1. In this system, RHAON and the Ethernet network are being used only for loudspeaker control and monitoring.

2. Neither CobraNet digital audio distribution nor analog audio distribution are available when AES3 format digital audio distribution is being

used; the AES3 format audio channels occupy the amplifier’s analog input channels.

3. The AES/EBU inputs on Iconyx amplifiers are fully balanced 110 Ohm inputs and are equipped with a balanced buffered loop through to

the next array.

4. The AES/EBU inputs on all Iconyx amplifiers are fully balanced 110 Ohm inputs and are equipped with a balanced loop through to the

next array. Their AES/EBU interface automatically detects the source sampling frequency, locks onto that sample rate whether it is 44.1

kHz, 48 kHz or 96 kHz and converts it to 48 kHz. As a result it is not necessary to re-initialize the system when running from AES/EBU

sources having different sample rates as long as the amplifiers are operating with a 48 kHz sample rate. If the amplifiers are set up for 96

kHz operation, the source sampling frequency must also be set to 96 kHz.

53

Users Manual

IC-R-II

Advertising
This manual is related to the following products: