Prepare an assembly area. Each module is 4 feet long, so

you need a flat surface at least 8 feet long to assemble an

IC16-R-II and 16 feet for an IC32-R-II. We suggest cover-

ing the assembly area with a heavy cloth or some other soft

material to prevent damaging the finish on the cabinets while

assembling them. Avoid resting the modules on their grille.

The modules are heavy and may deform the grille. Instead,

rest the modules on their sides or back.

Place the modules in their respective positions on the as-

sembly area.

Note: Be aware that If you purchased two or more IC8-R-II

arrays at different times and now want to turn them into an

IC16-R-II or larger array, the IC8-R-II array modules must be

of the same Firmware version. Firmware version 1.x must

not be mixed with Firmware version 2.x. Refer to page 58 for

details on updating firmware.

Before proceeding any further carefully check to make

sure none of the array modules are connected to the

Mains (main AC power line). If they are, disconnect them!

Removing the array module’s top plate exposes terminals

that carry AC power between the modules and pose a

shock hazard if the unit is connected to the AC power line

(mains).

You will first need to remove the top of the lower module and

the bottom of the top module, and the tops and bottoms of

any intermediate modules and their mounting brackets.

To remove an end cap, remove the eight machine screws

from each side of the cabinet and lift the end cap and its

mounting brackets out of the cabinet. Note that for clarity the

end cap was removed in the graphic.

Now, use the mounting bracket machine screws you removed

to install the two heavy joining plates. They will be packed

with the hardware. Tighten the screws lightly. The joining

plates need to be a little loose to slide easily into the other

cabinet. Align the two modules to be joined on a tabletop or

on the floor so that the top of the lower one and the bottom of

the upper one are close to one another, say 4” (10 cm) apart.

If you are assembling a “master & slave array, insert the free

end of the short ribbon cable into the socket on the second

module. Using a #1 Phillips screw driver, secure the connec-

tor with two 4-40 Phillips head screws (supplied). Make sure

the connectors are fully seated. If necessary, use a flashlight

to check because if the connectors are not seated properly,

you may have to disassemble the column again in order to

seat them correctly.

If you are assembling an All Master system, do not connect

the cables.