CONNECT

CobraNet Signal Routing

CobraNet devices transmit and receive digital audio (48 or 96 kHz, 16, 20 or 24 bit) in bundles of up to 8 channels. The number of chan-

nels per bundle can vary, depending on settings for latency and resolution. The number of bundles available depends on network band-

width.

Each CobraNet bundle has a number from the following ranges:

0:

Disables the receiver or transmitter.

1 thru 255:

Multicast mode (many receivers can access the same bundle).

256 thru 65,279:

Unicast mode (allows only one receiver to receive the bundle).

In order for CobraNet devices to communicate,

their Tx (Transmit) and Rx (Receive) bundle

numbers must match. RHAON devices are

equipped with two receivers and two transmit-

ters, their bundle numbers must be assigned

correctly so they can send and receive audio via

the network. RHAON software makes this easy.

In most cases the settings of a CobraNet source

will have already been established with the

source’s own proprietary software and can be

changed only with the manufacturer’s software..

However, it the manufacturer’s software allows

you can set or reset both receiver and transmit-

ter bundle settings of any device found on the

CobraNet network using RHAON software.

The first step in setting up CobraNet routing is

to drag the CobraNet Source that was detected

by Scan Network into the system.

The CobraNet Source and the devices connect-

ed to it must have the same Sample Rate and

Latency settings. Right clicking on the CobraNet

Source Icon will open a pop up screen showing

the Sample Rate and Latency settings. We sug-

gest you accept the Source’s default settings

unless you have a specific reason to change

them.

You will then want to check the device settings

to make sure they are the same as the Source’s

settings. The settings must be the same for the

source and for all devices connected to it.

While latency may be changed here via point-

and-click, the sample rate is pre-programmed

in the DSP firmware running in the loudspeaker.

You can switch sample rate by uploading the

appropriate firmware to your device. Please

refer to “APPENDIX III: Updating DSP Firmware” for information on how to upload new firmware to your device.

Next, check the bundle settings of the CobraNet Source device. The Source in our example has 4 Receivers and 4 Transmitters. The red

triangles on the left of its icon represent Rx bundles and the green triangles represent Tx bundles. Right clicking on one of the triangles will