KROHNE IFC 210 E-EEx EN User Manual

Page 19

Advertising
background image

Part A System installation and start-up Sect. 2.4

05/2002

IFC 210 E

19

2.4

Control inputs B1 and B2

The control inputs are galvanically isolated from the current output and all input circuits.

Setting data and functions can note down in Section 3.3.
Please also refer to Sect. 3.2 Factory settings.

Typical current inputs B1 and B2

B1/B2



B

All operating data and functions can be set,
see Sect. 4 and 5.10, Fct 1.07 and/or 1.08 for operator control

The control inputs must be operated in the passive mode.



Function of the control inputs

inactive active

no voltage

voltage present

Off

No functions

External range

High range

Low range

Hold measured values

Measured values follow the Hold measured values

measurement

Measured values at zero

Measured values follow the
measurement

Measured values set to
“zero“

Reset totalizer

inactive Reset

totalizer

Delete errors

inactive

Delete error messages


Connection diagram, see Sect. 2.5: diagram