Mechanical data - high efficiency, Mechanical data - high efficiency plus, Optichill chillers – Airedale OptiChill FreeCool 500kW - 1365kW User Manual

Page 28: Installation data, Chillers

Advertising
background image

OPTICHILL

Chillers

28

Chillers

Installation & Maintenance : 6564868 02/2013

Installation Data

MECHANICAL DATA - HIGH EFFICIENCY

OPC500HED8

OPC525HED8

OPC550HED8

OPC600HED10

OPC650HED10

Connections

Grooved type Coupling & Pipe Assembly

Water Inlet / Outlet

DN150 PN16

DN150 PN16

DN150 PN16

DN150 PN16

DN200 PN16

Water Drain / Bleed

in

1/2

1/2

1/2

1/2

1/2

Water System

Min. System Water Volume

l

1764

1849

1934

2079

2260

Max. System Operating Pressure

bar

10

10

10

10

10

OPTIONAL EXTRAS

Water Pump - ac Motor

(1)

In Line Pump - Fixed Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

70

66

63

56

76

Nom External Head Single - Larger

kPa

107

104

100

94

179

Water Pump - Inverter Driven Motor

In Line Pump - Variable Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

124

120

117

67

87

Nom External Head Single - Larger

kPa

124

120

117

155

174

OPC500HEDQ10

OPC525HEDQ10

OPC550HEDQ10

OPC600HEDQ10

OPC650HEDQ10

Connections

Grooved type Coupling & Pipe Assembly

Water Inlet / Outlet

DN150 PN16

DN150 PN16

DN150 PN16

DN150 PN16

DN150 PN16

Water Drain / Bleed

in

1/2

1/2

1/2

1/2

1/2

Water System

Min. System Water Volume

l

1750

1832

1915

2001

2087

Max. System Operating Pressure

bar

10

10

10

10

10

OPTIONAL EXTRAS

Water Pump - ac Motor

(1)

In Line Pump - Fixed Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

71

67

64

60

56

Nom External Head Single - Larger

kPa

108

105

101

97

159

Water Pump - Inverter Driven Motor

In Line Pump - Variable Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

124

121

118

71

67

Nom External Head Single - Larger

kPa

124

121

118

159

155

MECHANICAL DATA - HIGH EFFICIENCY PLUS

OPC500HE+D8

OPC525HE+D10

OPC550HE+D10

OPC600HE+D10

OPC650HE+D10

Connections

Grooved type Coupling & Pipe Assembly

Water Inlet / Outlet

DN200 PN16

DN200 PN16

DN200 PN16

DN200 PN16

DN200 PN16

Water Drain / Bleed

in

1/2

1/2

1/2

1/2

1/2

Water System

Min. System Water Volume

l

1825

1967

2067

2164

2297

Max. System Operating Pressure

bar

10

10

10

10

10

OPTIONAL EXTRAS

Water Pump - ac Motor

(1)

In Line Pump - Fixed Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

87

83

81

78

89

Nom External Head Single - Larger

kPa

124

121

118

116

192

Water Pump - Inverter Driven Motor

In Line Pump - Variable Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

140

137

135

89

100

Nom External Head Single - Larger

kPa

140

137

135

177

187

OPC500HE+DQ12

OPC525HE+DQ12

OPC550HE+DQ12

OPC600HE+DQ12

OPC650HE+DQ12

Connections

Grooved type Coupling & Pipe Assembly

Water Inlet / Outlet

DN200 PN16

DN200 PN16

DN200 PN16

DN200 PN16

DN200 PN16

Water Drain / Bleed

in

1/2

1/2

1/2

1/2

1/2

Water System

Min. System Water Volume

l

1850

1947

2044

2139

2234

Max. System Operating Pressure

bar

10

10

10

10

10

OPTIONAL EXTRAS

Water Pump - ac Motor

(1)

In Line Pump - Fixed Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

86

84

81

79

76

Nom External Head Single - Larger

kPa

123

121

119

116

179

Water Pump - Inverter Driven Motor

In Line Pump - Variable Speed Motor

Single Head or Run/Standby

Nom External Head Single - Standard

kPa

140

137

135

90

87

Nom External Head Single - Larger

kPa

140

137

135

177

175

(1)

Based on 12/7°C water temperature and 35°C ambient.