Meter gaskets and grounding, Meter/pipeline connection gaskets, Meter grounding – Badger Meter M-Series M5000 User Manual

Page 12: Conductive pipe grounding, Non-conductive pipe grounding

Advertising
background image

METER GASKETS AND GROUNDING

Gasket and grounding requirements must be considered when determining the meter location, orientation and application .

Meter/Pipeline Connection Gaskets

You must install gaskets (not provided) between the detector's

isolating liner and the pipeline flange to ensure a proper and secure

hydraulic seal . Use gaskets that are compatible with the fluid . Center

each gasket on the flange to avoid flow restrictions or turbulence in

the line .
During installation, do not use graphite or any electrically conductive

sealing compound to hold the gaskets . This could compromise the

accuracy of the measuring signal .
If you are using a grounding ring in the detector/pipeline connection,

place the ring between two gaskets . (See

"Non-Conductive Pipe

Grounding" on page 12

.)

GASKETS RECOMMENDED

Figure 15: Meter/Pipeline Connection Gaskets

Meter Grounding

Process pipeline material can be either electrically conductive (metal) or not electrically conductive (made of or lined with

PVC, fiberglass or concrete) .

MPORTANT

I

It is essential that the mag meter amplifier’s input ground (zero voltage reference) be electrically connected to the liquid media and

to a good, solid earth ground reference.

Conductive Pipe Grounding

To achieve an adequate ground, the meter body MUST be electrically connected to the liquid media . The mag meter flanges

are provided with grounding bolts for this purpose .
If the pipe material is electrically conductive, simply install grounding straps between these grounding bolts and the

mating flanges .
To ensure a good electrical connection at the mating flanges, we recommend that you drill and tap the flanges and install a

grounding screw (not provided) .
These grounding straps must be copper wire, at least 12 AWG size . They must be connected on both sides (inlet and outlet) of

the detector and to a local, earth ground .

Non-Conductive Pipe Grounding

MPORTANT

I

If the process pipe is not electrically conductive (PVC, fiberglass, cement-lined pipes or any other non-conductive material) and the

meter was not originally ordered with an optional grounding electrode, you must install a pair of grounding rings between the

mating flanges at both ends of the meter. See the following illustration.

In this case, the grounding straps should be connected to both of the

grounding rings and to a good, solid earth ground . Grounding rings

are available in stainless steel . If your fluid is too aggressive for stainless

steel, order a meter with the optional grounding electrode in a material

compatible with the fluid .

GASKETS RECOMMENDED

GROUNDING RING

GROUNDING RING

Figure 16: Non-Conductive Pipe Grounding

Meter gaskets and grounding