Mount Bracket to Amplifier
1 . Align bracket-mounting holes with amplifier mounting holes .
2 . Attach bracket to amplifier with supplied screws . Torque the screws to 80 inch-pounds .
Wiring Configuration
Wiring between the detector and the M5000 amplifier comes complete from the factory . If your installation requires the use

of conduit, we recommend that you follow these steps when wiring the detector to the amplifier .
1 . Carefully remove the wires connected to the terminal blocks that run to the M5000 amplifier or to the junction box . See

the chart below for a reference of wire color to terminal connection .

2 . Run cable through the conduit while retaining the wiring of the cable to the amplifier or the junction box, as supplied .
3 . Complete conduit assembly on both ends and rewire the cable as it was previously wired .
Wiring for Remote Configuration
Remote style M5000 amplifier models can be ordered with standard cables measuring 15, 30, 50 and 100 feet .

Junction Box

Connection

No.

Description

Wire Color

11

Coil

Red/Brown

12

Coil

Blue/White

13

Main Shield

Not Used

40

Empty Pipe

Pink

44*

Shield

Green

44*

Empty Pipe Shield

Shield Wire

45

Electrode

White

46

Electrode

Black

*Connections with the No . 44 are lying on the same potential .