Specifications – Badger Meter M-Series M5000 User Manual

Page 33

Advertising
background image

SPECIFICATIONS

Flow Range

0 .1…32 .8 ft/s (0 .03…10 m/s)

Accuracy

± 0 .4% of rate for velocities greater than 1 .64 ft/s (0 .50 m/s),

± 0 .0065 ft/s (± 2 mm/s) for velocities less than 1 .64 ft/s (0 .50 m/s)

Minimum Fluid

Conductivity

≥ 20 micro siemens/cm

Pressure Limits

Maximum allowable non-shock pressure and temperature ratings for steel pipe flanges,

according to American National Standard ANSI B16 .5 .

Examples: 150-lb flange, rated 285 psi at ambient temperature; 300-lb flange rated 740 psi at

ambient temperature .

Fluid Temperature

With Remote AmplifierE:

PTFE 302° F (150° C),

Hard rubber 178° F (80° C)

With Meter-Mounted AmplifierE:

PTFE 212° F (100° C),

Hard rubber 178° F (80° C)

Ambient Temperature

– 4…140° F (–20…60° C)

Flow Direction

Uni-directional or bi-directional . Two separate programmable totalizers for uni-directional

measurement .

Outputs (4 digital)

Galvanically isolated open collector, 30V DC maximum, 20 mA each, maximum output

frequency at 100 Hz

Outputs

ADE, High/low flow alarm (0…100% of flow), error alarm, empty pipe alarm, flow direction

Communication

RS232 Modbus RTU, IrDA

Empty Pipe Detection

Field-tunable for optimum performance based on specific application

Min-Max Flow Alarm

Programmable outputs 0…100% of flow

Low Flow Cut-Off

Programmable 0…10% of maximum flow

Galvanic Separation

Functional 50 volts

Pulse Width

Programmable 5…500 ms

Coil Power

Pulsed DC

Repeatability

± 0 .1%

Sampling Rate

Programmable from 1 to 63 seconds . Standard sampling period is 15 seconds .

Display

Two lines x 15 characters (7 on top + 8 on bottom), LCD display

Programming

Three external buttons

Units of Measure

Gallons, ounces, MGD, liters, cubic meters, cubic feet, imperial gallon, barrel, hectoliter and

acre feet

Battery Life

10 years

Power Supply

Internal lithium batteries 3 .6 volt

Processing

Low power microcontroller (16 bit)

Amplifier Housing

NEMA 4X (IP66), cast aluminum, powder-coated paint

Meter Housing Material

Standard: Carbon steel welded

Pipe Spool Material

316 stainless steel

Flanges

Standard: ANSI B16 .5 Class 150 RF Cast steel; Optional: 316 stainless steel & 300 lb cast steel

Liner Material

PTFE 0 .5…24", Hard rubber 1…24"

Electrode Materials

Standard: Alloy C; Optional: 316 stainless steel

Mounting

Detector-mount or remote wall mount (bracket supplied)

Meter Enclosure

Classification

NEMA 4X (IP66); Optional: Submersible NEMA 6P (IP67)-remote amplifier required

Junction Box Enclosure

Protection

For remote amplifier option: Powder coated die-cast aluminum, NEMA 4 (IP66)

NSF Listed

Models with hard rubber liner 4" size and up; PTFE liner, all sizes .

Cable Entries

1/2" NPT Cord Grip

Optional Stainless Steel

Grounding Rings

Meter Size

Thickness (of 1 ring)

Up through 1" 0 .135"

12…24"

0 .187"

Specifications

MAG-UM-00219-EN-03

Page 33