Measure Menu

Measure

Flow Unit

U

This parameter establishes the unit of measure for the flow rate and full scale flow . Changing this

parameter readjusts the full scale flow parameter . For example, changing from GPM to GPS would

change the full scale flow from 60 gal/min to 1 gal/s .

Display

Flow Unit

Display

Flow Unit

L/s

Liters/Second

gal/s

Gallons/Sec .

L/min

Liters/Minute

gal/min

Gallons/Min .

L/h

Liters/Hour

gal/h

Gallons/Hour

m

3

/s

Cubic Meters/Sec .

MG/d

MillionGallons/Day

m

3

/min

Cubic Meters/Min .

IG/s

ImperialGallons/Sec .

m

3

/h

Cubic Meters/Hour

IG/min

ImperialGallons/Min .

ft

3

/s

Cubic Feet/Sec .

IG/h

ImperialGallons/Hour

ft

3

/m

Cubic Feet/Min .

oz/min

Ounce/Min

ft

3

/h

Cubic Feet/Hour .

bbl/min

Barrel/Min

Totalizer Unit

U

This parameter establishes the units of measure for the totalizers .

Display

Totalizer Unit

L

Liters

hL

Hectoliter

m

3

Cubic Meters

ft

3

Cubic Feet

gal

U .S . Gallons

MG

Million Gallons

IG

Imperial Gallons

bbl

Barrel

oz

Fluid Ounces

ac/ft

Acre per foot

Full Scale Flow

S

This parameter sets the maximum flow that the system is expected to measure . This parameter has

influence on other system parameters, which include:

• Low Flow Cutoff – Changes to full scale flow affect the measuring cut-off threshold of the meter
• Alarm Outputs – Changes to full scale flow adjusts the thresholds for generating setpoint alarms
• Pulse Outputs – Changes to full scale flow adjusts the pulse frequency and duty cycle

Change the full scale flow based on the meter size and the application’s requirements . Verify that the

full scale flow falls within the meter’s suggested flow range limits .
Flow Range: 0 .1…32 .8 ft/s (0 .03…10 m/s)
The full scale flow is valid for both flow directions .

OTEE:

N

If the flow rate exceeds the full scale setting of more than 100%, a FLOW_OVERLOAD_

WARNING message indicates that the configured full scale range has been exceeded . However,

the meter will continue to measure . This will affect the latency of the pulse outputs and

possibly cause overflow .

Using the m5000 main menu programming options

MAG-UM-00219-EN-03