Digital output wiring diagrams, Digital output selections – Badger Meter M-Series M5000 User Manual
Page 17

Digital Output Wiring Diagrams
Positive Pulse Logic
Negative Pulse Logic
Figure 22: Digital Output Wiring Diagram
Digital Output Selections
Output 1
Output 2
Output 3
Output 4
Forward Pulse Output
Reverse Pulse Output
Flow direction
(Forward vs . Reverse)
ADE
Flow Setpoint
(0…100% of full scale, resolution 1%)
Flow Setpoint
(0…100% of full scale, resolution 1%)
Empty pipe alarm
Empty pipe alarm
Error alarm
Error alarm
Off
Test
Can be used with AMR when the pulse width is set to
50 milliseconds .
—
Outputs are configurable for Pulses/Unit (PPU) and Pulse Width (PW) . The PW is configurable from 5…500 milliseconds, with a
frequency limit is 100 Hz . The PPU is displayed using an automatically selected resolution .
The high/low flow alarm functionality is configurable for maximum and minimum setpoints as a percentage of full-scale flow .
Configurable values are settable from 0…100% in 1% increments .
=
Configuring input/output (i/o)
MAG-UM-00219-EN-03
Page 17
August 2014