5 parameter, Device name, Fu sets bus error – NORD Drivesystems BU2200 User Manual

Page 26: Ip gateway, Powerlink cycle, Present error

Advertising
background image

5 Parameter

26

BU 2200 GB-3813

P162

Device name

(Device name)

SK TU3-POL

SK xU4-POL

8 bit

ASCii

{ 0 }

Name of the bus module in the POWERLINK network

If no device name is given, the module logs into the Powerlink network with the default name
"Powerlink <NodeID>-0xED"

The settings are only adopted after a restart of the module.

Pos : 53 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P163

– FU setzt Busfehl er [SK xU x-POL] @ 4\mod_1378887891220_388.doc x @ 94490 @ @ 1

P163

FU sets bus error

(FI sets bus error)

SK TU3-POL

SK xU4-POL

8 bit

0 … 1

{ 1 }

If this function is enabled (1), the bus module sends an error message in case of a fault. With the
setting (0), a status message is sent.

Pos : 54 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P164

– IP Gateway [SK xU x- POL] @ 4\mod_1378888096666_388.doc x @ 94514 @ @ 1

P164

... [-01]

... [-04]

IP Gateway

(IP Gateway)

SK TU3-POL

SK xU4-POL

8 bit

0 ... 255

{ [-01] = 192 }

{ [-02] = 168 }

{ [-03] = 100 }

{ [-04] = 254 }

Parameterised IP address of the gateway consisting of four bytes.

The Ethernet POWERLINK Standardization Group (EPSG) recommends that the IP address
remains at the the default address.

The setting is only adopted after a restart of the module.

[-01] = IP High (Net-ID)

[-02] = IP (Net-ID)

[-03] = IP (Net-ID)

[-04] = IP Lo (Host)

Pos : 55 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P165

– POWER LIN K Z yklus [SK xU x-POL] @ 4\mod_1378888765733_388.doc x @ 94538 @ @ 1

P165

POWERLINK Cycle

(POWERLINK cycle time)

SK TU3-POL

SK xU4-POL

16 bit

400 … 20000 µs
{ 1000 }

The bus cycle time which is set is used for synchronisation with the Manage Node.

Pos : 56 /Anl eitungen/ Elektroni k/ Bus s yst eme/5. Par ameter/ P17x I nf ormati ons Paramet er

– Bus , allgemei n @ 3\mod_1369132034911_388.doc x @ 69995 @ 5 @ 1

General Bus InformationParameters (P17x)

Parameter

Setting value / Description / Note

Device

Type

Pos : 57 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P170

– Aktuell er Fehler [SK xU x- ..., SK EBIOE] @ 3\mod_1368776868873_388.doc x @ 69554 @ @ 1

P170

... [-01]

... [-02]

Present Error

(Present Error)

SK

EB…

SK TU3-

SK xU4-

8 bit

0 ... 9999

Error present in the bus module. The error message is reset when the supply voltage is switched
off.

[-01] = Present module error

[-02] = Last error message from module

For a list of possible error messages, please refer to the section "Error Monitoring and
Error Messages".

Pos : 58 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P171

– Softwar e-Version [SK xU x-..., SK EBIOE] @ 3\mod_1368785436095_388.doc x @ 69604 @ @ 1

Advertising