5 Parameter

30

BU 2200 GB-3813

P184

... [-01]

... [-06]

NMT Statechangecount

(NMT Status change)

SK TU3-POL

SK xU4-POL

8 bit

0 ... 2

31

Counter for the error which caused the last change of state The counter readings are deleted
after a restart!

[-01] = Loss of SoC (cyclic data lost)

[-02] = Jitter of SoC (Timeout of cyclic data)

[-03] = Loss of PReq (MN not responding)

[-04] = Loss of SoA (acyclic frame lost)

[-05] = Collision (data collision)

[-04] = CRC Error (transfer error)

Pos : 71 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P185

– Akt. IP Adresse [SK xU x-...] @ 3\mod_1369128043016_388.doc x @ 69872 @ @ 1

P185

... [-01]

... [-04]

Present IP Address

(Present IP Address)

SK TU3-

SK xU4-

8 bit

0 ... 255

Displays the present IP address

[-

01] … [-04] = IP Address

xxx . xxx . xxx . xxx

Pos : 72 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P186

– Akt. IP Subnetz mas ke [SK xU x-...] @ 3\mod_1369129573087_388.doc x @ 69896 @ @ 1

P186

... [-01]

... [-04]

Present IP Sub-net Mask

(Present IP Sub-net mask)

SK TU3-

SK xU4-

8 bit

0 ... 255

Displays the present IP sub-net mask.

[-

01] … [-04] = IP Sub-net mask

xxx . xxx . xxx . xxx

Pos : 73 /Anl eitungen/ Elektroni k/ Bus s yst eme/5. Par ameter/ PO WERLINK [ BU 2200]/ Par ameter Fr equenz umrichter [SK xU x- PO L] @ 4\ mod_1379408292183_388. doc x @ 98762 @ 2 @ 1

5.2 Frequency Inverter Parameters

Various parameters of the frequency inverter are relevant for the commissioning of the bus system or
the frequency inverter in the bus system and may need to be changed.

A detailed description of the inverter parameters can be found in the manual for the relevant frequency
inverter.

Param
eter

Parameter name

Recommended setting

Remarks

SK 5xxE

SK

180E … SK

2xxE

P120

Option monitoring

Not available, or not
relevant for SK TU3
modules

{1} = Auto

P509

Control word source

{8} = Ethernet TU

{3} = System bus

P510

Setpoint source

{0} = Auto

{0} = Auto

P513

Telegram timeout

{0.5} = 0.5s

{0.0} = Off

Do not set this value too low

P543

Actual BUS value

Acc. to the function:

According to the
function:

SK 54xE and SK

180E …

SK 2xxE: up to 5 actual
values each

P544

Actual BUS value 2

Acc. to the function:

Not available

Only SK

500E … 535E

P545

Actual BUS value 3

Acc. to the function:

Not available

Only SK

500E … 535E

P546

Funct. Setpoint BUS
value

Acc. to the function:

According to the
function:

SK 54xE and SK

180E …

SK 2xxE: up to 5 setpoints
each

P547

Funct. BUS setpoint 2

Acc. to the function:

Not available

Only SK

500E … 535E

P548

Funct. BUS setpoint 3

Acc. to the function:

Not available

Only SK

500E … 535E

Info parameters

P700

Present

Operating

Fault / Warnings / Reason for