5 Settings and displays

BU 0070 GB

Subject to technical alterations

19

Parameter

Setting value / Description / Note

Available in Option

P547

Function bus - Setpoint 2

Always visible

0 ... 24

[ 0 ]

valid for SK

5xxE

This parameter is identical to P546.

P548 (P)

Bus setpoint 3

Always visible

0 ... 20

[ 0 ]

valid for
SK 300/700/750E

In this parameter, a function is assigned to the delivered setpoint 3 (SW3) for bus control. Only
available if P546 is

≠ 3.

This parameter is identical to P547.

P548

Function bus - Setpoint 3

Always visible

0 ... 24

[ 0 ]

valid for SK

5xxE

This parameter is identical to P546.

P551

Drive profile

Always visible

On / Off

[ 0 = Off ]

The InterBus Drivecom profile is activated with this parameter.

0: Switch off profile

1: Switch on profile as per DRIVECOM 21



Information parameters:

P745

Module version

Always visible

0 ... 32767

Software version of the installed module

(InterBus technology unit Index 01)

Array level: [01]

Technology

unit

[02]

Customer

unit

[03] Special extension unit

P746

Module status

Always visible

0000 ... FFFF hex

Status of installed modules (see 5.2)

(InterBus technology unit Index 01)

Array level: [01]

Technology

unit

[02]

Customer

unit

[03] Special extension unit

NOTE

When activated, the functions block voltage, quick stop, remote control and error
acknowledgement
are available at the control terminals (local). To operate the drive, a high
signal must be present on the digital inputs being used before the drive can be enabled.