NORDAC InterBus Operating Manual

28

Subject to technical alterations

BU 0070 GB


Sw itch-on block

Standby

activated

Operation

enabled

Emergency

stop active

Error reaction

active

Error

From every device status

3

4

5

6

8

4

5

5

Not on standby

Sw itching on the inverter

Loading relay applied

Error

Error reaction
ended

Bit0 = 0:

Shut dow n

& Bit1 = 1:

Enable voltage

& Bit2 = 1:

Enable pulses

(xxxx x1xx xxxx x110)

Bit 3 = 0:

Block operation

Bit0 = 1:

Sw itch on

Bit3 = 1:

Enable operation

Bit2 = 0:

Emergency stop

Bit1 = 0:

Block voltage

v Bit2 = 0:

Emergency stop

Priority of control com m ands:
1. Block voltage
2. Emergency stop
3. Shut dow n
4. Enable operation
5. Sw itch on
6. Block operation
7. Reset error

Designation of states:
1: Bit 0 = 0
2: Bit 6 = 1
3: Bit 0 = 1
4: Bit 1 = 1
5: Bit 2 = 1
6: Bit 5 = 0
7: Bit 2 & Bit 3 = 1
8: Bit 3 = 1

3

5

2

3

3

6

4

2

2

1

2

3

7

8

f = 0 reached
(Emergency stop ended)

Bit7 0

Î

1

error acknow ledgement

Control bits
0. Ready for operation / shut dow n
1. Block / enable voltage
2. Enable pulses / emergency stop
3. Block / enable operation
4. Operation condition / block RUE
5. Enable / stop RUE
6. Block / enable setpoint
7. Error acknow ledgement (0

Î

1)

10. Control data valid / invalid

11. Rotation right
12. Rotation left
14. Parameter set Bit 0
15. Parameter set Bit 1

4

5

6

Bit4 = 0:

Move dow n emergency ramp and

remain in "Operation enabled"

Bit5 = 0:

Hold frequency

Bit6 = 0:

Setpoint = 0%

Bit0 = 0:

Shut dow n

5

Bit3 = 1:

Enable operation

& Bit0 = 1

: Sw itch on

2

Internal status machine

2