NORDAC SK 150E

12

Technical modifications observed

BU 0100 GB

3.4 Display and settings

The following controls are available for the SK 150E:

3.4.1 Status LEDs

These LEDs are visible through a lateral transparent screw plug.

red LED:

OFF

no fault present

green LED:

Blinking briefly

Long pause

Operational (Standby):
System voltage and temperature are OK, no [RUN-R]
release has been applied

Blinking briefly

Short pause

Release [RUN-R]has been applied, phase angle is active

Permanently

on

--- Motor

turns with maximum torque

(Motor receives full voltage)

red LED:

ON

a fault is present

green LED:

Blinking 1 x

Pause

[RUN-RIGHT] was already active before applying the 24
VDC.

Blinking 2 x

Pause

Automatic feature is OFF and the system voltage is
absent or the motor temperature is too high

Blinking 3 x

Pause

Automatic feature is ON and the system voltage is absent
or the motor temperature is too high

Blinking 5 x

Pause

One phase of the system voltage is missing.

Blinking 7 x

Pause

Frequency deviates from 50/60 Hz by more than +/-2 Hz.

Dip switch

(Operating

mode)

Status LEDs

(red / green)

Potentiometer

(Torques/Times)

Transparent screw plug

To permit viewing of

status LEDs from outside

Slide switch

(Automatic ON/OFF)

Advertising